FAQ
Sales & Support
- Q1How should I terminate the unused input pins?
- Q2Do you have any examples of register settings for connecting panels?
- Q3Can you recommend specific manufacturers or models for SDRAM?
- Q4Do you offer related software or device drivers?
- Q5Do you offer an evaluation board?
- Q6Who do I contact in the event the product fails to operate normally?
- Q7Please explain about auto increment condition for the parallel interface.
- Q8Do you offer an IBIS model?
- Q1How should I terminate the unused input pins?
- ATerminate the pins as indicated below.
TEST[1:0]: Connect to GND
SCANEN: Connect to GND - Q2Do you have any examples of register settings for connecting panels?
- AYes. Please refer to the application notes here. Also the panel setting sheet "S1D13517 Panel Setting" is also available at following URL.
- Q3Can you recommend specific manufacturers or models for SDRAM?
- AEpson has no recommendation in particular . The SDRAM used on our S1D13517 evaluaion board from Integrated Silicon Solution Inc. Please refer to Integrated Silicon Solution Inc. for SDRAM details.
- Q4Do you offer related software or device drivers?
- ARelated software and device drivers are available at the URL below.
- Q5Do you offer an evaluation board?
- AWe provide the S1D13517 evaluation board (S5U13517P00C200).
Please contact a Seiko Epson sales representative. - Q6Who do I contact in the event the product fails to operate normally?
- APlease contact your local Seiko Epson representative available at the following Sales & Support.
- Q7Please explain about auto increment condition for the parallel interface.
- ADownload the Hardware Specification from the URL below and refer to the following details. The HCS# pin signal described in Figure 11.1 to 11.4 (see pages 93 to 97) stays active "low" in the automatic increment mode. But, as long as the AC timing matches the timing described in Figure 8.6 (see page 33), it can be changed to "high" every time the register address increments.
"S1D13517 Display Controller Technical Manual" is available at following URL.
- Q8Do you offer an IBIS model?
- AYes. Please refer to the attached file.
S1D13517 IBIS model (60KB)